+6019-475 8268 / 019-478 8268
sales@dreshler.com.my

Compact Ultrasonic Sensor - IMP+

Previous 1 / 5 Next

Compact Ultrasonic Sensor - IMP+ PULSAR Non-Contacting Measurement Level Measurement


Download Files

imp-plus-datasheet.pdf (480.82 KB)
Non Contacting Ultrasonic Measurement

The IMP+ non-contacting ultrasonic sensor is designed to be used wherever you need an accurate and reliable level measurement. Its digital echo processing means the IMP+ is perfect for slurries, liquids, or anywhere you need a display telling you the level or analog output to interface with your site control system or drive a display.

There are several measurement ranges available from 0 m to 10 m and each can be wired for 2 or 3-wire operation. All options feature an LCD display and digital temperature measurement and compensation. When combined with Pulsar’s PC Suite, users are able to download, analyze and store echo profiles, set up the IMP’s parameters, install the new firmware to your IMP, and add a flow curve to be able to configure level to flow linearization.
_____________________________________________________________________________________________________________________


TECHNICAL SPECIFICATIONS:
 

General Specifications
Spec: Description:
Dimensions 186 mm (H) x 133 mm (D) (5.24 in (H) x 7.32 in (D))
Cable Entry:  2 off cable glands 4.5 mm to 10 mm (0.18 in to 0.39 in); Torque to 2 NM
Mounting:  IMP3 - 3 m (10 ft) version: 1.5 in BSP/NPT
IMP 6 - 6 m (20 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (33 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Nominal 1kg (2.2 lb)
Enclosure Protection IP67
Temperature (Process) -4 0°C to +65 °C (-40 °F to +149 °F )
Temperature (Ambient) -40 °C to +80 °C (-40 °F to +176 °F)
Input Voltage Range 11-30 V, 3.5-22 mA
Accuracy ±0.25% or 6 mm (0.24 in) whichever is greater
Resolution ±0.1% or 2 mm (0.08 in) whichever is greater
4-20mA Outputs Resolution 5 μA; both active and passive outputs
Temperature Compensation Via internal temperature sensor 0.5 °C (± 32.9 °F) accuracy. Level and volume conversion are installed allowing linearisation for tank shapes.
PC Interface All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Recent Updates